< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=1385595982820197&ev=PageView&noscript=1" />

Aluminum is strong and durable, but it conducts heat. A thermal break solves that: an insulating strip separates the inside and outside of the profile, so heat and cold cannot travel straight through the frame. Every SKATE window and door uses thermal break profiles.

 

How a Thermal Break Works

 

Each SKATE profile has three zones. The outer chamber handles water and drainage, the middle chamber holds the thermal break strips that slow heat transfer, and the inner chamber forms the airtight seal. The wider the thermal break, the better the insulation.

 

PA66 Thermal Break Strips

 

Our profiles are high-precision 6063-T5 aluminum with PA66 nylon thermal break strips made in-house - not PVC. PA66 withstands high temperatures, resists oxidation and corrosion, and keeps its strength over the life of the window. On our seamless welded windows the strips are rated to 260 °C, so they are not damaged during the 230 °C powder-coating cure.

 

Less Condensation, Warmer Rooms

 

When the inside of the frame stays warmer, moisture is less likely to condense on it in winter. Combined with argon-filled insulating glass, this keeps rooms comfortable near the window and helps prevent mold on sills and reveals.

 

Profile and Glass Options

 

Series

Type

Glass configuration

76M

Tilt and turn / casement, 1.8 mm walls

5+24A+5 double or 5+12A+5+12A+5 triple

95 Passive

High-insulation casement

5+22A+5+22A+5 triple

110 Lift-and-Slide

Sliding door

5+20A+5 double

110H

Heavy-duty casement, 2.0 mm walls

[ ]

 

Tested U-Values

 

Whole-window U-values measured to GB/T 8484-2020 (window size about 1.5 × 1.5 m):

 

Series

Glass

U-value (K)

90 Casement (90 mm frame)

5 Low-E + 12A + 5 + 12A + 5 Low-E

0.9 W/m²K (grade 10)

80 Casement

5 Low-E + 12A + 5 + 12A + 5 Low-E

0.9 W/m²K (grade 10)

75 Tilt & Turn

5 double-silver Low-E + 12Ar + 5 double-silver Low-E + 9Ar + 5 + 0.76 PVB + 5, warm-edge

1.1 W/m²K

W110 Passive

5 double-silver Low-E + 18A + 5 double-silver Low-E + 15A + 5

1.4 W/m²K

75 Casement

5 + 12A + 5 + 12A + 5

1.4 W/m²K

In the W110 test, with −20 °C on the cold side and 20 °C on the warm side, no condensation or frost formed on the room-side surface.

 

FAQ

 

Q1: Are your thermal break strips PVC or PA66?

A: All SKATE systems use PA66 nylon thermal break strips, which we produce ourselves.

Q2: Can I get a Uw value for my windows?

A: Yes. Tested U-values range from 0.9 to 1.4 W/m²K across our 70, 75, 80, 90 and W110 series. The exact value depends on the series, glass and size; tell us your configuration and we will send the matching test report.