(1) When the height of the window sill is lower than 800mm (the height of the window sill of residential buildings is lower than 900mm) and there is no balcony or platform outside the window, protective facilities must be provided.
(2) Waterproofing measures need to be taken on the exterior window sill, and the gaps between the window frame and the window sash, and between the window sash and the window sash should be taken care of. At the same time, the inner window sill should be 15mm higher than the outer window sill.
(3) The opening form of the window should be convenient to use, safe and easy to clean. Windows opened on the ground floor need to have protective measures. The bottom height of the window sash opening to the public walkway should not be less than 2m.
Due to unfamiliarity with national standards, many practitioners in the door and window industry refer to top-hung windows as bottom-hung windows and bottom-hung windows as top-hung windows. In fact, the definition of the national standard is very regular. For exterior windows, the position of the hinge (hinge) when a person stands on the indoor side is the "up, down, left, and right" in the window name.